U-Line Corporationwww.u-line.comPhone (414) 354-0300 • FAX (414) 354-7905Service & Parts Tech Lines Phone (800) 779-2547 • FAX (414) 354-5696U-Lin
Service and Parts Manual10The objective of this section is to assist theservice technician in diagnosing problems thatare related to installation and/
11Plumbing installation must observe all state and local codes.These guidelines must be followed when installing drain lines to prevent water from flo
Service and Parts Manual12Plumbing installation must observe all state and local codes. All water anddrain connections MUST BE made by a licensed/qual
13Automatic Clean CycleTo maintain operational efficiency, clean unit every six months (depending on water condi-tions more or less frequent cleaning
Service and Parts Manual14On initial start-up or restart (closing of bin thermostat), the toggle switch is in the iceposition:1. The water solenoid va
HOT GAS VALVEWATER FILL VALVEWATER CIRCULATION PUMPCOMPRESSORCONDENSER FANENERGIZED NOTE: THE FREEZE / HARVEST CYCLE TIMES WILL VARY DUE TO OPERATING
The thermistor senses the refrigeration system “High side” temperature. This is used inconjunction with the control board to determine the length of t
17Low Side Pressure ChangesThe chart above shows the low side pressure changes through the cycles of a CLR60 unit.It shows that during a harvest cycle
Service and Parts Manual18Compressor PinsTo measure start winding resistance, measure across the C - S pins.To measure run winding resistance, measure
19System Suction Suction Compressor Condenser Capillary Evaporator WattageCondition Pressure Line Discharge TubeNormal Normal Slightly below Very hot
NOTESService and Parts Manual2
Service and Parts Manual20The ice thickness control is factory set to maintainan ice bridge of 1/16" to 1/8". A dimple in eachcube is normal
21NOTEThese characteristics will vary depending on operating conditions, condensercleanliness, installation, and application.Ambient Temp/Water Temp d
Service and Parts Manual22NEVER attempt to repair or perform maintenance on the unit until the mainelectrical power has been disconnected.1. Unit Does
5. Low Ice ProductionCause Remedy High ambient temperatures around unit Lower ice rate is normal with highambient temperatures Deposit build-up o
10. Low (or no) Ice ProductionCause Remedy Dirty condensing coil (Control board Clean condensing coillight shows rapid flash) Stalled condenser f
15. Not Freezing (compressor and fan not operating)Cause Remedy No electrical power to unit Make sure unit is plugged in and outlet has power Rock
Service and Parts Manual26TIME ADJ.FUSETRANSWITH U-LINE P60 DRAIN PUMPLIGHT231CONTROL BOARDL1THERMISTOR SOLENOIDWATER INLETOVERLOADRELAYSOLENOIDHOT GA
27CLR60A11151235413610971617842181421161CLR60 - Clear Ice MakerItem Description Part No.1 Drain Tube (Clear) 2820-S2 Rocker Switch CL60 22853 Water Va
Service and Parts Manual28CLR60B78912103564CLR60 - Clear Ice MakerItem Description Part No.1 Pump 316132 Pre-formed Tube (White) 31615-S3 Water Trough
29CLR60C11914105181312476152CLR60 - Clear Ice MakerItem Description Part No.1 Compressor 5406-S2 Bypass Valve Assembly 2749-S604 Condenser Assembly 22
3Three generations of pride in quality manufacturing and design improvements are builtinto all U-Line products.We are proud and excited to announce th
Service and Parts Manual30How to Order Replacement Parts1. Locate the illustration(s) for the model you are servicing.NOTESome models may have more th
FAX PARTS ORDER FORMFAX # 414-354-7905Account# ______________________________________ Ship to: ______________________________________Bill to: ________
P.O. Box 245040Milwaukee, WI 53224-9540Phone 414.354.0300FAX 414.354.7905Printed in U.S.A. – March 2000 P/N 42002
Service and Parts Manual4NOTES
5Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3Limited Warranty . . . . . . .
Service and Parts Manual6Warranty StatementOn 11-1-98, U-Line Corporation modified the warranty provided with our units. We havesignificantly improved
7U-Line Corporation warrants each U-Line product to be free from defects in materialsand workmanship for a period of one year from the date of purchas
Service and Parts Manual8When submitting claims for warranty payment, please follow these guidelines.You can use any form you would normally use to bi
9Do not attempt to service or repair the unit until you have read the entire procedure.Safety items throughout this manual are labeled with Warning or