Plumbing installation must observe all state and local codes. All water and
drain connections MUST BE made by a licensed/qualified plumbing contractor.
Failure to follow recommendations and instructions may result in damage
and/or harm.
If a gravity drain connection is not available, and you have not purchased the CLR60 with
factory installed pump, install the U-Line P60 drain pump in the rear compartment of the
ice maker. The U-Line P60 drain pump is available through your Dealer, or direct from
U-Line with complete installation instructions.
If a gravity drain connection is not available, and you have not purchased the CLR60 with
factory installed pump, U-Line strongly recommends the use of the U-Line P60 drain
pump. If a pump other than the U-Line P60 drain pump is to be used, it must meet the
following specifications:
• It must be UL listed and have a UL listed, 120 VAC, 3-wire grounded power cord.
• Overall maximum outside dimensions of 8-3/4" wide x 5-3/4" deep x 7-3/4" high.
• Minimum flow rate of 15 gallons per hour at 10 feet of lift.
• It must have a sealed sump which does not allow water leakage in the case of a power
outage, restricted drain or pump failure.
• It must have a check valve in the discharge line to prevent waste water return to the
pump.
• It must have an overflow protection control which will shut off power to the ice maker
in the event of a pump failure.
• Operating temperature range of 50°F to 110°F (10°C to 40°C).
In the event of a power outage, restricted drain or pump failure, the failure to use the
U-Line P60 drain pump or a pump with the above listed specifications, could result in
substantial water leakage and pooling with severe and costly water damage and related
consequential damages and harm.