6 U-Line Product Operation
123 54
To check the actual product temperature in the unit.
1. Partially fill a plastic (nonbreakable) bottle with water.
2. Insert an accurate thermometer.
3. Tighten the bottle cap securely.
4. Place the bottle in the desired area for 24 hours.
5. Avoid opening the unit during the testing period.
6. After 24 hours, check the temperature of the water. If required,
adjust the temperature control in a small increment (See
ADJUSTING TEMPERATURE).
Causes which affect the internal temperatures of the
cabinet include:
Temperature setting.
Ambient temperature where installed.
Installation in direct sunlight or near a heat source.
The number of door openings and the time the door is open.
The time the internal light is illuminated. (This mainly affects
product on the top rack or shelf.)
The front grille or condenser are obstructed.
Checking Product Temperature
Interior Lighting
Normal Operation. Opening the door will cause the interior of
the cabinet to illuminate.
Use the LIGHT icon (5) on the control panel to change the lighting
functions.
Blackout (Sabbath) Mode. The interior of the cabinet and
control display remains darkened until reset. (Blackout (Sabbath)
Mode is not Star K certified).
To turn the lights and display OFF.
1. Press and hold the LIGHT icon (5) for ten seconds and release
(the °F symbol will flash briefly at the end of the ten second
period).
2. The interior light and control display (3) will go dark until the
mode is reset.
3. NOTE: Although the display will not be visible, the temperature
controls in the unit remain active, and preserve the interior
temperature.
To exit the Blackout (Sabbath) Mode, repeat Step 1.