www.U-LineService.com 8 05/2007
CLR2160/CLRCO2175 Ice Makers
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A circuit (normal household current). See
Electrical Specifications on Page 20.
Water Supply
The unit requires a 1/4” O.D. soft copper water supply
line. For more information see Page 15.
Drain
The unit’s generous 7-inch drain connection height
extends the distance the unit can be located from a
gravity drain. For more information see Page 15.
IMPORTANT
Drain can NOT be located directly below unit. Unit has a
solid base that will not allow unit to drain below itself.
Environmental Requirements
Many U-Line models are designed to operate in harsh
outdoor environments. Special considerations include the
following:
The units are designed to operate between 50°F (10°C)
and 11F (40°C). High ambient temperatures (110°F
[40°C] or higher) may reduce the unit’s ability to reach
low temperatures and may also reduce the ice
production rate for those models with ice makers.
If the ambient temperature is expected to drop below
45°F (7°C), drain all water from the unit to prevent
freezing damage not covered by the warranty.
For best performance, keep the unit out of direct
sunlight and away from heat generating equipment.
For best performance and life outdoors, place under a
counter or provide shelter of some kind.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
disappear when the humidity drops.
Side-By-Side Installation
Instructions CLR2160
For a complete refreshment center, install your CLR2160
Clear Ice Maker beside a U-Line Refrigerator, Combo, or
Wine Captain Model (see Figure 14 for typical cut-out).
Note that each Side-By-Side Installation will be different.
Cut-out width for a side-by-side installation is the total
of the widths listed under Cut-Out Dimensions in each
unit’s Installation Guide.
For example:
Placing a CLR2160 Clear Ice Maker next to a 2115 series
unit would require a cut-out width of:
15-3/16" + 15-3/16" = 30-3/8".
Placing a CLR2160 Clear Ice Maker next to a 2175 series
unit would require a cut-out width of:
15-3/16" + 24-3/16" = 39-3/8".
No trim kit is required. However, 1/4-inch space needs to
be maintained
between the units to ensure
unobstructed door swing.
Units must operate from separate, properly grounded
electrical receptacles placed according to each units
Electrical Specifications.
Acceptable
Location
Preferred
Location
for CLR2160
Receptacle
1"
7"
24"
34-1/4"
to
35-1/8"
1/4" Space
Between Appliances
Figure 14
Typical Side-By-Side Cut-Out