14 CLR2160, CLRCO2175
b. Touch and release the DOWN ARROW (Figure
13, 2) button three times, then release the UP
ARROW button (Figure 13, 1).
c. The display (Figure 13, 3) will switch to “0” to
confirm the thickness adjustment mode has been
selected.
2. The factory setting is “0,” and the total range of
adjustment is -5 to +5. Use the UP ARROW button to
raise the setting and thicken the ice bridge, or the
DOWN ARROW button to lower the setting to thin the
ice bridge.
IMPORTANTIMPORTANT
Ice thickness adjustment should only be made one
increment at a time. Allow ice maker production to
stabilize for 24 hours before rechecking ice
thickness.
3. Touch and release the LIGHT
(Figure 13, 4)
button key
to exit the ice thickness adjustment mode.
4. Remove all ice from the storage bin.
Figure 14
5. Ice cubes in any given batch will vary, so it is necessary
to choose cubes from the sample area
(Figure 14, 1)
for comparison when making adjustments. If further
adjustments are desired, repeat Steps 1 through 4.
Drain Pump
Interval - Not Required
A drain pump, if installed, requires no routine
maintenance. To check its operation, pour 1 gallon of
cool, fresh water into the ice bin. The drain pump will run
and water should drain freely from the bin.
Leveling
IMPORTANTIMPORTANT
It is extremely important that Clear Ice models are
level. If not level, the ice mold will not fill evenly.
Figure 15
A unit that is not level can cause a reduction in ice rate,
uneven sized cubes or water spilling into the storage area,
which will cause the ice in the bin to melt prematurely
(Figure 15).
When checking the level, remember that floors near
drains have a tendency to slope towards the drain.
Figure 16
Use a level to check the levelness of the unit from front to
back and from side to side. Level should be placed along
top edge and side edge as shown (Figure 16).
Figure 17
6. If the unit is not level, adjust the feet on the corners of
the unit as necessary
(Figure 17)
.
7. Check the levelness after each adjustment and repeat
the previous steps until the unit is level.